Broan 947224-Q1 TV Mount User Manual


 
FIG. 4
PRESTIQUE
MEDICINE CABINET
WARNING: Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
Prepare cabinet.
1. Carefully remove all packing material.
Determine location.
1. The commonly accepted height of bath cabinets is 64" from the finished
floor to the center of the mirror area. However, height may be adjusted
to individual preference.
2. It is recommended that the cabinet be located such that the mounting
screws may be screwed into wall studs to provide maximum strength.
3. Provide 120 VAC power cable through the wall material, directly
behind the light box.
Mount cabinet.
1. Measure and mark four (4) clearance holes in cabinet back at wall stud
locations. Use angle brackets to locate upper holes. (Fig. 1)
2. Drill ¼" dia. clearance holes through cabinet back.
3. Hold angle brackets in place over top set of holes. Mount brackets to
underside of light housing with #6 x ½" screws.
4. Hold cabinet in place and make sure it is level. Screw cabinet to wall
studs.
NOTE: Irregularities in wall surface may cause distortion of cabinet
body when mounted. Place shims between cabinet and wall at appro-
priate corners.
OPTION (If wall studs are not available):
4. Hold cabinet in place and make sure it is level. Mark wall through all four
(4) clearance holes.
5. Set cabinet aside and drill holes in wall material for molly bolts or wall
anchors (not provided).
6. Mount cabinet to wall material.
Connect electrical wiring.
WARNING: Before wiring this product, switch power off at service en-
trance and lock service panel to prevent power from being switched on
accidentally.
1. Remove reflector from wrapper.
2. Remove protective plastic film from reflector and snap light cups onto
sockets.
3. Make electrical connections between house wires and fixture wires on
rear of reflector: black to black, white to white, and greenwire to a per-
manent ground. (FIG. 2)
4. Attach reflector to cabinet.
Mount shelves.
1. Choose the location for the shelves from the five (5) sets of holes lo-
cated on the inside of the cabinet.
2. Insert two (2) shelf tabs into holes, at desired location on one side of the
cabinet. Repeat on the other side, being sure to use holes at the same
height, so the shelf will be level.
3. Set shelves on pins.
Attach mirror doors.
1. Remove wrapping from mirror door. Remove hinge brackets and pres-
sure plates from parts bag.
FIG. 1
FIG. 2
WIRING
ACCESS
HOLE
LIGHT
SOCKET
CUP
MIRROR
DOOR
A99042675C
HINGE
BRACKET
(Pressure plate
beneath
backside)
NYLON
WASHER
BACKSIDE OF
MIRROR DOOR
PRESSURE
PLATE
FIG. 3
HINGE
BRACKET
FIG. 6
FIG. 5
2. Peel paper backing from two (2) pressure plates and affix plates to
backside of mirror door at upper-left and lower-left corners. (FIG. 3)
3. Slide hinge bracket(s) over top of door(s) and lightly tighten screws
against pressure plate(s). (FIG. 3)
4. Place a nylon washer on the pin of the remaining hinge bracket and
insert hinge bracket(s) into hole(s) in bottom of frame.
5. Lift mirror door(s) and insert top hinge bracket(s) into hole(s) in top of
frame. (FIG. 4) Slide bottom of mirror door(s) into lower hinge bracket(s)
(FIG. 5) and lightly tighten screws against pressure plate(s). (FIG 6)
6. Remove the 1" diameter strike plate(s) from the parts bag. Peel off the
paper backing and affix plate(s) to rear of mirror door(s) at the lower
corner(s) opposite the magnetic catch(es).
7. Clear urethane discs are furnished to prevent finger marks on mirror
face. To mount: Remove paper backing and affix to mirror face ½” from
bottom and outside edge.
REFLECTOR
URETHANE DISC
STRIKE
PLATE
MAGNET
SHELF
SHELF
TABS
SCREW
#6 x 3/8”
CLEARANCE
HOLES
SCREW
#6 x ½”
ANGLE
BRACKET
All electrical connections must be made in accordance
with local code ordinances. If you are unfamiliar with
methods of installing electrical wiring, secure the ser-
vices of a qualified electrician.
WHITE TO WHITE
BLACK TO BLACK
GREEN TO
GROUND
WIRE
INSTRUCTIONS FOR
WALL-MOUNT INSTALLATIONS
MODEL NO. SIZE FINISH
942224-P1 24” White
942230-K1 30” White
942236-K1 36” White
947224-Q1 24” Oak
947230-Q1 30” Oak
947236-Q1 36” Oak
SCREW
#8 x 1½”
For help, call
us toll free!
1-800-637-1453