Fujitsu IRMC S2/S3 Universal Remote User Manual


 
iRMC S2/S3 185
iRMC S2/S3 - Information, firmware and certificates
Update file
File in which the firmware image is stored.
I The files listed below each allow you to update one component of
the iRMC S2/S3 firmware every time TFTP is started (runtime
firmware and SDR record).
The file rt_sdr_<D-number>_4_08g_00.bin is also available for
some PRIMERGY servers / blade servers. This allows you to
update all the components of the iRMC S2/S3 firmware in a single
operation using a TFTP server.
dcod<FW-Version>.bin
Updates the runtime firmware.
<SDR-Version>.SDR
Updates the SDR record.
Flash Selector
Specify what iRMC firmware is to be updated.
You have the following options:
Auto - inactive firmware
The inactive firmware is automatically selected.
Low Firmware Image
The low firmware image (firmware image 1) is selected.
High Firmware Image
The high firmware image (firmware image 2) is selected.
Ê Click Apply to activate your settings.
Ê Click TFTP Test to test the connection to the TFTP server.
Ê Click TFTP Start to download the file containing the firmware image from the
TFTP server and to start updating the iRMC S2/S3 firmware.