196 iRMC S2/S3
Power Management
● System Identification LED
As long as the System Identification LED is on, the iRMC S3 will not
enable 0Watt mode.
● Advanced Video Redirection (AVR)
If an AVR session is currently active, the iRMC S3 will not enable
0Watt mode. Once all AVR sessions have been finished (i.e, no AVR
is active), the iRMC S3 will enable 0Watt mode.
● Remote Storage Server (RSS), Telnet/SSH Sessions
If an RSS session or an SSH/Telnet session is currently active, the
iRMC S3 will not enable 0Watt mode. This prevents the remote
interface connections to the iRMC S3 from being lost.
● AC power fail
If an AC fail occurs and the PSU (Power Supply Unit) is in the 0Watt
mode or in the scheduled mode, the PSU will return to system
standby. Depending on the power restore policy settings (see
page 192), the iRMC S3 determines whether the server is to be
powered on. If the power restore policy is set to Always power off, an
AC fail will never result in 0Watt mode. 0Watt mode may be reached
after the next system power on.
Scheduled
Enables 0 Watt mode and also displays the 0 Watt Technology
Administration Window. The 0 Watt Technology Administration Window allows
you to specify a time interval at which the PSU is awoken from 0Watt
mode and thus both remote management and Wake-on-LAN (WOL) can
be used.
Figure 108: Power Options page, 0 Watt Technology Administration window
Start Time
Defines the beginning (hh:mm) of the time interval.