Fujitsu IRMC S2/S3 Universal Remote User Manual


 
90 iRMC S2/S3
Using AVR
5.2.3 Local Monitor Off" function
The Local Monitor Off function of the iRMC S2/S3 allows you to power down the
local monitor of the managed server for the duration of your AVR session. In this
way, you ensure that the inputs you make and the actions you perform on the
local monitor on the server using AVR cannot be seen. The identification LED
flashes to indicate "Local Monitor Off" mode on the server.
You configure the “Local Monitor Off” function on the Advanced Video Redirection
page of the iRMC S2/S3 web interface (see page 302). After you have
configured the system appropriately, you can switch the local monitor of the
server on and off from the remote workstation as follows:
In Full Control mode in an AVR session using the Extras menu
directly on the Advanced Video Redirection page with administrator or OEM
permissions
You can also configure that the local monitor is always switched off
automatically whenever a new AVR session is started.
The current status of the local monitor is shown in the AVR window in blue
letters to the top right of the integrated special keys:
The local monitor is always switched on and cannot be switched off, as
the Enable Local Monitor Off option (see page 307) is deactivated.
Local Monitor On
The local monitor is on, but can be switched off.
Local Monitor Off
The local monitor is off, but can be switched on.
Local Monitor always off
The local monitor is always switched off and cannot be switched on
because a high-resolution graphics mode has been set on the managed
server (see table 3 on page 86).