M2488 PRODUCT GUIDE MEDIA CHANGER COMMANDS
March 1997 CG00000-011503 REV. A 6-41
6-4 MC (MEDIUM CHANGER) INQUIRY/CHANGE DEFINITION VITAL
PRODUCT DATA PAGES
This section describes the VPD (Vital Product Data) pages and parameters used by the MC Inquiry and
Change Definition commands. The MC VPD parameters include information such as configuration data
(vendor identification, product identification, model). The supported MC VPD pages are shown in the
following table.
6-4.1 General VPD Page Format
The General VPD page format is:
Table 6-50. Supported MC VPD Page Codes
VPD
PAGE
CODE
VENDOR
UNIQUE
PAGE
DESCRIPTION
USED BY THE
FOLLOWING MC CMDS.
INQUIRY
CMD.
CHANGE
DEF. CMD.
00 N
List of the vital product data pages supported by
this target.
YN
81h N Implemented operating definition page. Y N
82h N ASCII implemented operating definition page. Y N
C2h Y Product identification page. Y Y
Table 6-51. VPD Page Format
BITS
BYTES
7 654321 0
0
Peripheral Qualifier Peripheral Device Type
1
Page Code
2
Reserved
3
Page Length (n - 1)
4-N
VPD parameters