Fujitsu M2488 VCR User Manual


 
DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-30 CG00000-011503 REV. A April 1997
0x10
0x08 Read EDRC-NC 3 bytes 00, mode
04h
0x05 A non SUCCESS status was returned from
the function call rm_host_rd_complt. A error
was detected in the SDDP_HI-hdxs register.
0x07 A byte for byte miscompare was detected on
the data bytes stored in the SPC receive
buffer.
0x10 0x09 Read EDRC 3 bytes 00, mode 00h 0x01 A host data path end of transfer was not
detected in the allotted time.
0x02 when transferring data from the SPC data_fifo
to the SPC receive_buffer, the SPC-ssig regis-
ter did not have the expected bits set:
SCSI_REQ, SCSI_BSY, xfer_phase.
0x03 when transferring data from the SPC data_fifo
to the SPC receive_buffer, the SPC-ssig regis-
ter did not have the expected bits set:
~SCSI_REQ, SCSI_ACK, SCSI_BSY,
xfer_phase.
0x04 All the data expected to be transferred from
the SPC data_fifo to the SPC receive_buffer
was not transferred.
0x05 A non SUCCESS status was returned from
the function call rm_host_rd_complt. A error
was detected in the SDDP_HI-hdxs register.
0x07 A byte for byte miscompare was detected on
the data bytes stored in the SPC receive
buffer.
0x10 0x0A Write EDRC 3 bytes 00, mode
10h
0x01 after a write diag operation was initialized in
the spc chip, the SPC-status register did not
have one of the following:
SPC_data_trans_rdy, SPC_busy, or
SPC_data_reg_empty.
0x02 when transferring data from the SPC send
buffer to the SPC data fifo, the SPC-ssig regis-
ter did not have the expected bits set:
SCSI_REQ, SCSI_BSY, xfer_phase.
0x03 when transferring data from the SPC send
buffer to the SPC data fifo, the SPC-ssig regis-
ter did not have the expected bits set:
~SCSI_REQ, SCSI_ACK, SCSI_BSY,
xfer_phase.
0x04 A non SUCCESS status was returned from
the function call rm_request_wrtbuffer.
Table F-12. Routine 10 - EDRC Control Signals Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE
ERROR
CODE
DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES