DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-48 CG00000-011503 REV. A April 1997
0x13
0x0A Read Sync host_count-high /
compression error / sgd
host_count-high errs
0x01 Failed to receive data end-of-transfer signal in
SDDP hdxs register.
0x02 Incorrect SPC SCSI control signal status wait-
ing for REQ signal assertion.
0x03 Incorrect SPC SCSI control signal status wait-
ing for REQ signal deassertion.
0x04 Data transfer length error reported by SPC
0x05 SDDP failed to report expected data compres-
sion and sync host count error.
0x06 SDDP failed to report expected data compres-
sion host count error.
0x07 SDDP failed to report expected data compres-
sion host CRC error.
0x08 SDDP failed to report expected CRCA error.
0x13 0x0B Read Sync host_count-low / com-
pression error / sgd host_count-
low errs
0x01 Failed to receive data end-of-transfer signal in
SDDP hdxs register.
0x02 Incorrect SPC SCSI control signal status wait-
ing for REQ signal assertion.
0x03 Incorrect SPC SCSI control signal status wait-
ing for REQ signal deassertion.
0x04 Data transfer length error reported by SPC
0x05 SDDP failed to report expected data compres-
sion and sync host count error.
0x06 SDDP failed to report expected data compres-
sion host count error.
0x07 SDDP failed to report expected data compres-
sion host CRC error.
0x08 SDDP failed to report expected CRCA error.
0x13 0x0C Read Sync host_crc / compression
error / sgd host_crc errors
0x01 Failed to receive data end-of-transfer signal in
SDDP hdxs register.
0x02 Incorrect SPC SCSI control signal status wait-
ing for REQ signal assertion.
0x03 Incorrect SPC SCSI control signal status wait-
ing for REQ signal deassertion.
0x04 Data transfer length error reported by SPC
0x05 SDDP failed to report expected data compres-
sion and sync host CRC error.
Table F-15. Routine 13 - EDRC Error Detection Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE
ERROR
CODE
DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES