Fujitsu M2488 VCR User Manual


 
DIAGNOSTIC TESTS AND ERROR CODES M2488 PRODUCT GUIDE
F-66 CG00000-011503 REV. A April 1997
Table F-17. Routine 50 - 4M Tones Test Error Codes
ROUTINE TEST TITLE
ERROR
CODE
DESCRIPTION
0x50
* 4M Tones Tests 0xE0 DVL card connection was not detected by the
DTC.
0xE1 A working tape was not loaded, or the tape
drive was not READY when the test started.
0xE2 The tape drive is not READY.
0x50 0x01 Write 4M tones test 0xE3 The tape (or magazine) is FILE PRO-
TECTED.
0x01 Formatter command not accepted error.
0x02 Timeout waiting for Formatter Command
Complete.
0x03 Formatter error during command execution.
0x50 0x02 Read-backward 4M tones test 0x01 Formatter command not accepted error.
0x02 Timeout waiting for Formatter Command
Complete.
0x03 Formatter error during command execution.
0x50 0x03 Read 4M tones test 0x01 Formatter command not accepted error.
0x02 Timeout waiting for Formatter Command
Complete.
0x03 Formatter error during command execution.
DIAGNOSTIC TESTS