M2488 PRODUCT GUIDE DIAGNOSTIC TESTS AND ERROR CODES
April 1997 CG00000-011503 REV. A F-71
0x80
0x05 Servo Diag: Tachometer test 0x06 The machine reel turns too slow
0x08 File reel tachometer phase error in forward
direction
0x0A File reel tachometer phase error in backward
direction
0x0D File reel turns too slow
0xE3 Servo command was not accepted; sense
information was built
0xE4 Servo command was accepted but failed to
complete within 60 seconds
0xE5 Servo error occurred that was not reported as
a diagnostic error.
0x80 0x06 Servo Diag: ACL/FACL test 0x01 The servo command completed in error and
valid sense information was built. Byte 19 of
the sense information, which can be found in
Table (ACL) or Table (FACL), gives a more
detailed description of the error.
0xE3 Medium changer not detected; this test cannot
be run without a medium changer attached.
0xE4 Magazine eject failed.
0xE5 Servo reported error occurred during ACL/
FACL test initialization.
0x80 0x07 Servo Diag: Manual Sensor test 0x80 Servo error reported during Manual Sensor
test execution.
0xE3 Medium changer not detected; this test cannot
be run without a medium changer attached.
0x80 0x08 Servo Diag: Manual ACL test 0x01 Servo error reported during Manual ACL test
execution.
0xE3 Medium changer not detected; this test cannot
be run without a medium changer attached.
Table F-19. Routine 80 - Servo Diagnostic Error Codes (Continued)
ROUTINE TEST TITLE
ERROR
CODE
DESCRIPTION
DIAGNOSTIC TESTS
AND ERROR CODES