M2488 PRODUCT GUIDE MTU DIAGNOSTIC SPECIFICATIONS
April 1997 CG00000-011503 REV. A H-21
H-6 DIAG RESULT DATA
The MTU DIAG execution result takes up 512 bytes.
Explanation
The DIAG execution result data is divided into groups. Each group requires 32 bytes. The result
data is stored in an area corresponding to the DIAG group executed under the SEND DIAGNOSTIC
command.
struct diag result {
unsigned short error code;
unsigned short diag result data[15];
} diag output parm [16];
error code : 0x0000 ------ Normal end
error code : 0xFF00 ------ Break end
error code : 0x00XX ------ Error end ( XX : Error code )
The DIAG result data format is shown as follows:
DIAG result format
ERROR RESET
: name : code
DIAG command code : ERROR RESET command : 0x70 or 0xF0
DIAG parameter 1 : :
DIAG parameter 2 : :
DIAG parameter 3 : :
DIAG parameter 4 : :
DIAG parameter 5 : :
DIAG parameter 6 : :
DIAG parameter 7 : :
DIAG parameter 8 : :
DIAG parameter 9 : :
execute time : :
stop time : :
execute count : :
reserve : :
Result of Loading time (“M1:LOAD”)
: measurement result : unit
0- 1 error code : :
2- 3 result data 1 : Loading time : 1/10 sec
4- 5 result data 2 : Clutch winding time : 1/10 sec
6- 7 result data 3 : Threading time : 1/10 sec
8- 9 result data 4 : BOT shaking time for normal CTG : 1/10 sec
10- 11 result data 5 : BOT shaking time for E-CTG : 1/10 sec
12- 13 result data 6 : :
14- 15 result data 7 : :