26
Operation
When RM-LP25U is connected to a camera, all features that
are available on RM-LP25U can only be controlled via RM-
LP25U, and control of these features using the camera is
disabled.
Switches on the camera that are disabled, as well as
disabled menu items are as follows.
Ⅵ Switches that are disabled
● GAIN
● SHUTTERT
● WHT.BAL
● FULL AUTOT
● User 1, 2 and 3 with the following features assigned
BARS
B.STRETCH1-5
B.COMPRESS1-5
AE LEVEL+
AE LEVEL-
Memo:
● SHUTTER will also be disabled if the setting is
AVARIABLEB or below A1/30B.
● FULL AUTO is forcibly set to AOFFB regardless of the
switch status.
Ⅵ Menu items that are disabled
Memo:
● CINEMA is forcibly set to AOFFB. To adjust MATRIX, make
use of the menu on the camera.
● GAMMA is fixed to the menu setting value of camera
before connecting remote control.
However, it is forced to ASTANDARDB if the menu setting
value of camera before connecting remote control is
AOFFB.
Ⅵ Remote Cable
Manufactured by Hosiden Corporation (Length: 5 m)
Operation of Connected
Camera
Menu Display
Menu Page
Function
GY-HD250
GY-HD251
GY-HD200
GY-HD201
CAMERA
OPERATION
AE LEVEL REMOTE REMOTE
BARS REMOTE REMOTE
CAMERA
PROCESS[1/2]
MASTER
BLACK
REMOTE REMOTE
DETAIL REMOTE REMOTE
CAMERA
PROCESS[2/2]
BLACK REMOTE REMOTE
KNEE REMOTE REMOTE
LEVEL REMOTE REMOTE
ADVANCED
PROCESS
CINEMA [OFF]T [OFF]T
GAMMA [STANDARD]T [STANDARD]T
[CINEMA]T [CINEMA]T
[FILMOUT]T [FILMOUT]T
LEVEL REMOTE REMOTE
WHITE
BALANCE
WHITE
PAINT R
REMOTE REMOTE
WHITE
PAINT B
REMOTE REMOTE
Remote Connector
Specifications
Pin
No.
Signal Description Level IN/OUT
1GND GND ^^
2 RM/CTL Operate Control +5V OUT
3GND GND ^^
4 SID2 Received Data +5V IN
5 SID1 Transmitted Data +5V OUT
6+9V Vcc +9V IN
5 6
3 4
21