6-4 Alarm Recording
Alarm recording functions during timelapse recording. When an alarm signal is input to the rear panel’s ALARM IN terminal, an
index code is recorded on the tape and the VCR automatically switches to the 2H (SP) or 6H (EP) mode for realtime recording
of the alarm situation. Normal timelapse recording is restored after the preset alarm recording duration has passed.
* Alarm recording will not start from the Pause mode.
* An index code (VISS) is recorded at the start point of the alarm recording as an alarm cue signal.
* During alarm recording, a +12 V signal is output from the rear panel’s ALARM REC OUT terminal.
* If a new alarm signal is input during alarm recording, alarm recording restarts from that point.
6 RECORDING
On-screen
"ALARM"
indication
Extinguished
Extinguished
Shown Shown
Extinguished
Extinguished
Display "AL"
indication
Lit
Lit
Blinking
Blinking
Record mode
Timelapse
mode
Timelapse
mode
Timelapse
mode
2H (SP)
/6H (EP)
2H (SP)
/6H (EP)
Timelapse
recording
Timelapse
recording
Timelapse
recording
Alarm
recording
Alarm
recording
Alarm signal input
Alarm signal input
5 Menu switches are provided for alarm recording mode,
alarm recording duration, buzzer ON/OFF in alarm
recording, and Forced Stop mode ON/OFF at tape end.
5 During alarm recording, the [AL] indication is lit on the
VCR and the [ALARM] indication is lit on the monitor
display. After alarm recording is complete, the “AL”
indication blinks on the display to show that an alarm
signal has been input.
* If the alarm recording function is activated a hundred
times a day or more, a malfunction may occur because
the guaranteed range is exceeded.
If you want to use this unit more than a hundred times
a day, set the recording speed mode to 2H/6H and
perform regular maintenance, replacing parts as
necessary.
“AL” indication