ALARM INPUT INSTALLATION
The DX8000 has either 8 or 16 dry contact alarm inputs, depending on your system’s configuration. Each input is programmed to function as
either a normally open or normally closed circuit.
To wire an alarm input:
1. Insert the green terminal blocks into the alarm sockets on the back panel of the recorder.
2. Connect one wire from the source device to one of the sensor input terminals 1 through 16.
3. Connect a second wire from the source device to a GND terminal.
4. Refer to the Operation/Programming manual for information on how to program the alarm inputs.
Figure 13. Alarm Terminal Installation
IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9
IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16
OUT16OUT15OUT14OUT13OUT12OUT11OUT10
OUT9
OUT9
OUT8OUT7OUT6OUT5OUT4OUT3OUT2OUT1
ALARM INPUTS RELAY OUTPUTS
1 2245678GND
910111213141516
1 2245678GND
910111213141516910111213141516
CRT
ALARM
OUTPUT 1
GND