Chapter 1 Producing Sounds
Reset to Default Factory Settings (Factory Reset)
The Factory Reset operation undoes any settings you have
changed and discards any edits you have made to its
patches. If you have settings or patches you wish to preserve,
use the Bulk Dump operation (p. 37) to save them to an
external MIDI device, such as a sequencer, before performing
the Factory Reset operation.
Performing a Factory Reset
1. Press [SYSTEM] to enter System mode.
2. Press [PARAMETER] to select “FACTORY RESET.”
fig.1-04
3. Turn [VALUE] to select the parameter—or group of
parameters—you wish to reset.
All:
Restores all settings to their original state.
System:
The System settings will be restored to their factory
settings.
User Patch:
Patch settings will be restored to their original state.
PC Number:
Program Change numbers are re-assigned according to
the current order of the patches.
For more detailed information about the “PC Number,” refer
to “Re-assigning Program Change Numbers in the Order of
Patches” (p. 97).
4. When you have selected the desired parameters, press
[WRITE].
The message “Sure ?” appears, asking you to confirm
that you want to go ahead and perform the Factory Reset
operation.
fig.1-05
5. To execute the operation, press [WRITE] again.
“Now Writing...” appears in the display. In a moment,
the GR-33 automatically returns to Play mode,
completing the factory Reset.
To cancel the operation, press [PLAY].
* This means that the processing of data is in progress. Once
you press [WRITE], be sure not to turn off the power until to
return to Play mode.
<About Factory Reset>
The procedure for restoring the GR-33’s internal settings
to the state they were in when the unit left the factory is
called a “Factory Reset.”
At the time of purchase, the GR-33’s user patches (A11 to
D84) are the same as preset patches E11 to H84. These
patches, as well as the GR-33’s system settings—
including pickup sensitivity and the MIDI channels used
for sending and receiving MIDI data—can be returned to
their original factory-fresh state.