Sony DSR-70P DVD Recorder User Manual


 
Chapter 4 Time Data and Sub LCD Menu
Chapter 4 Time Data and Sub LCD Menu 65
Synchronizing the Internal
Timecode Generator With an
External Signal — External Lock
You can synchronize the internal timecode generator
of this unit by inputting an external timecode signal
(LTC).
To synchronize to an external timecode
signal
Connect the external timecode (LTC) signal to the TC
IN connector, and set the TC INT/EXT switch to the
EXT position.
This starts the synchronization of the internal timecode
generator to the external timecode signal. Once the
synchronization is achieved, the internal timecode
generator continues to be synchronized even when the
external timecode signal is disconnected.
Note
When the input mode is SDTI or i.LINK (the SDTI or
i.LINK indicator is present in the subsidiary LCD),
then setting the TC INT/EXT switch to the EXT
position automatically synchronizes the internal
timecode generator to the timecode transferred through
the SDTI (DSBK-150) or i.LINK (DSBK-140)
interface.
Note that when the TC INT/EXT switch is set to EXT,
the advance mode and frame count mode (DSR-70
only) are automatically set as follows.
Advance mode: free running
Frame count mode (DSR-70 only): the same as the
external timecode signal (drop frame or non-drop
frame)
Checking the synchronization to the
external signal
Press the STOP button to stop this unit, then press the
REC/SEQ button.
Watch the time counter display, and check that the
values displayed coincide with the external timecode
values.