Sony DSR-DR1000AP DVD Recorder User Manual


 
95
Troubleshooting
Chapter 8 Maintenance and Troubleshooting
If such an alarm message appears, a connection or
operation error may have been made, or condensation on
heads may have occurred. Follow the direction indicated
on the monitor screen.
Note
To display alarm messages on the monitor screen, it is
necessary for the monitor to be connected to the SUPER
connector, and set the following menu items to ON.
CHARA. DISPLAY (see page 63)
•ALARM (see page 64)
•REF ALARM (see page 64)
Alarm messages and associated directions
Alarm message on monitor screen
(Cause)
Direction Alarm message in time
counter display
A non-standard signal is being used for
input video.
Use a standard signal. VIN NON-STD
A non-standard ref. signal is being used
for REF. VIDEO.
Use a standard signal. REF NON-STD
Abnormal settings selected in setup
menu.
Correct the setup menu settings. Contact your Sony
dealer if this alarm message appears again after
making corrections.
ILL. SETUP!
Audio mixing mode cannot be changed
during recording.
REC mode!
Audio REC (recording) mode cannot be
changed during recording.
REC mode!
Counter mode is selected. Use the COUNTER SELECT button to light the TC or
U-BIT time data type indicator in the display section.
CNT mode!
Input selection cannot be changed in
REC (recording) mode.
REC mode!
Input signal does not conform to
DVCAM/DV format.
Unknown Sig
Input signal is 625/50. (For DSR-
DR1000A)
625/50 sig! (For DSR-
DR1000A)
Input signal is 525/60. (For DSR-
DR1000AP)
525/60 sig! (For DSR-
DR1000AP)
Input video is not detected. Check the VIDEO indicator in the INPUT signal
display section and supply an appropriate video
signal.
No INPUT!
Input video signal does not synchronize
with REF. VIDEO signal.
Use a reference video signal. ILL. REF!
Invalid subclip. There is an invalid subclip setting, for example a Mark
Out point before a Mark In point. Correct the setting.
CLIP set !
MODE CANNOT BE CHANGED
DURING DUAL RECORDING.
To exit simultaneous recording and playback mode,
press the R button in the PANEL SELECT section to
stop recording and then press the R button again so
that the button goes out.
Dual REC !
Moisture has been detected. Keep the power on and wait until this alarm message
disappears.
HUMID!
Rec inhibit mode is selected. Set the REC INHIBIT menu item (see page 62) to
OFF.
REC INHI.!
Remote mode is selected. Set the LOCAL/REMOTE switch to LOCAL. REMOTE!
Simultaneous recording and playback. Stop the unit by pressing the STOP button and then
switch with the buttons in the PANEL SELECT
section.
Dual Rec !
TC EXTERNAL is selected. Set the TC MODE menu item (see page 65) to INT
PRESET.
TC EXT!
TCG REGEN mode is selected. Set the TC MODE menu item (see page 65) to INT
PRESET.
REGEN mode!