Sony HXCU-D70 TV Cables User Manual


 
33
Appendix
Design and specifications are subject to change without
notice.
Pin assignment
INTERCOM
* When the signal is unbalanced, connect the GND signal of the
microphone to pin 1.
INTERCOM/TALLY/PGM
Dimensions
Note
Always verify that the unit is operating properly before use.
SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY
KIND INCLUDING, BUT NOT LIMITED TO,
COMPENSATION OR REIMBURSEMENT ON ACCOUNT
OF THE LOSS OF PRESENT OR PROSPECTIVE
PROFITS DUE TO FAILURE OF THIS UNIT, EITHER
DURING THE WARRANTY PERIOD OR AFTER
EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER
REASON WHATSOEVER.
DOWN
IRIS/MB
ACTIVE
ALARM
EXT
AUTO
UP
HD CAMERA CONTROL UNIT HXCU-D70
MASTER BLACK
MASTER GAIN
ECS
ON
DOWN
UP
BLACK/FLARE
WHITE
AUTO
IRIS
BLACK
SHUTTER
CALL
CUSTOM
SW1 SW2
WHITE
ATW PRESET
BARS STANDARD
PANE L
ACTIVE
MENU ENTER
CONTROL
NETWORK
DISP CANCEL
MENU
PROD
ENG
MIC-ON
OFF
POWER
INTERCOM
CABLE
ALARM
CAM
POWER
OPEN
LOCK
ON
OFF
424 (16
3
/
4
)
66
(2
5
/
8
)
395 (15
5
/
8
)
Unit: mm (inches)
482 (19)
No. Signal Specifications
1 INTERCOM MIC IN (Y)/
(GND)*
-20 dBu (CARBON)
-40 dBu (ECM)
-60 dBu
(DYNAMIC, BALANCE/
UNBALANCE)
2 INTERCOM MIC IN (X)
3GND GND
4 INTERCOM L OUT
5 INTERCOM R OUT
No. Signal Specifications
1 ENG (R) (X) OUT ENG SYSTEM RECEIVE
0 dBu BALANCED
2 ENG (R) (Y) OUT
3 ENG (G) GND for ENG
4 ENG (T) (X) IN ENG SYSTEM TALK
0 dBu BALANCED
5 ENG (T) (Y) IN
6 PGM1 (X) IN -20 dBu/0 dBu/+4 dBu
(Selectable with CCU Menu)
7 PGM1 (Y) IN
8 PGM1 (G) IN
9 GND GND for TALLY OUT
10 PREVIEW OUT OPEN COLLECTOR
(Max. 30 mA)
11 R TALLY (X) IN ON: SHORT
OFF: OPEN
12 R TALLY (G) IN
13 GND CHASSIS GND
14 PROD (R) (X) OUT PROD SYSTEM RECEIVE
0 dBu BALANCED
15 PROD (R) (Y) OUT
16 PROD (G) GND for PROD
17 PROD (T) (X) IN PROD SYSTEM TALK
0 dBu BALANCED
18 PROD (T) (Y) IN
19 NC
20 NC
21 GND CHASSIS GND
51
2
3
4
- EXT VIEW -
13
25 14
1
- EXT VIEW -