The state of the test tone output is also shown on the
monitor by an image of the audio listening room.
This is convenient for adjusting each speaker level.
y
• If “1A CENTER SP” on the SET MENU is set to NONE, the
center channel sound is automatically output from the left and
right main speakers.
Note
• If the test tone cannot be heard, turn down the volume, set the
unit in the standby mode and check the speaker connections.
4 Press LEVEL repeatedly
to select the speaker to be
adjusted.
y
• Once you press LEVEL, you can also select the speaker to be
adjusted by pressing d. (Pressing u changes the selection in
the reverse order.)
5 Press j / i repeatedly to
adjust the output level of
the effect speakers so that
the output level coming
from each speaker is the
same.
While adjusting, the test tone is heard from the
selected speaker.
6 When the adjustment is complete, press
TEST.
The test tone stops and the
current DSP program appears
on the front panel display and
on the video monitor.
y
• The tonal quality of the center speaker can be adjusted by using
“5 CENTER GEQ” on the SET MENU (see page 43).
• You can increase the output levels of the effect speakers
(center, left rear and right rear) to +10 dB. If the output level of
these speakers is lower than that of the main speakers even
after you have increased the output level of these speakers up to
+10 dB, set “1E MAIN LEVEL” on the SET MENU to –10 dB
(see page 42). This setting decreases the main speaker output
level to about one-third of the normal level. After you have set
“1E MAIN LEVEL” on the SET MENU to –10 dB, adjust the
levels for the center and rear speakers again.
TEST DOLBY SUR.