3M 733 Cable Box User Manual


 
2 78-8135-7466-8-B
1.0 Kit Contents
Note: Visually inspect all components. If any component is missing or appears damaged, do not install.
Call 3M customer service at 1-800-426-8688 for a replacement product.
1.1 Kit Contents SLiC 530/533/733-2 Port 0.61 Cable
Entry Bracket 80-6113-2344-7
A. Cable Addition Bracket Assembly (1)
B. Cap
C. Multi-port Grommet (1)
D. Hose Clamp (1)
E. Pair Saver
F. 3M
Scotchlok
Shield Bond Connector 4460
with LSM Clamp (2)
G. 10-32 UNF Flange Nut (2)
H. Lubricant (1)
I. Instruction Manual 78-0013-2695-4 (Not Shown)
A
B
C
D
E
F, G
H
1.2 Kit Contents SLiC 530/533/733-2 Port-MSM 0.61
Cable Entry Bracket 80-6113-8403-5
A. Cable Addition Bracket Assembly (1)
B. Cap
C. Multi-port Grommet (1)
D. Hose Clamp (1)
E. Pair Saver
F. 3M
Scotchlok
Shield Bond Connector 4460
with LSM Clamp (2)
G. 10-32 UNF Flange Nut (2)
H. Lubricant (1)
I. Instruction Manual 78-8128-0289-6 (Not Shown)
A
B
C
D
E
F, G
H
2.0 Cable Preparations
2.1 Per company practice, remove sufficient cable
jacketing to allow for slack storage and splicing needs
(approximately 5 feet).
2.2 Trim central strength members on both cables
approximately 3" (76 mm) from the end of the cable
jacket.
Note: When using ribbon fiber cable, leave a minimum of
2" (50 mm) of central tube.
2.3 Insert cables into the multi-port grommet so that
1.25" to 1.75" (32–45 mm) of cable jacketing is
exposed past the inside edge of the grommet.
Note: A small amount of lubricant provided in the kit
may be placed on the leading edge of the cable to ease
installation into the grommet.
Note: Place and tighten a cable tie around the grommet
or you may also place a couple of wraps of Scotch
®
Linerless Rubber Splicing Tape 130C around cable to
provide a better seal.
Note: Carefully follow safety, health and environmental
information given on product label or the Materials
Safety Data Sheet for the lubricant.
1.25"–1.75"
(32–45 mm)
3" (76 mm)