2. Access to the analyzers
2. ACCESS TO THE ANALYZERS
Overview
• Removing the Top Cover
• Removing the EMC plat
Particularities
Depending on the projector the procedure to access the analyzers m ay be different.
In the RSIM6 projector the top cover can be removed without removing the lens whereas in the 6500/6 400i projector the lens has
to be removed to allow cover removal.
In the images the cove r color may not always coinc ide with t he reality.
2.1 Removing the Top Cover
Location
The Top Cover is located on the Top side of the projector.
Image 2-1
Top Cover Location
Necessary Tool
• Flat blade screw d ri ver 8 mm.
Be sure the Pro jecto r Handle is in the inserted position when removing the Top Cover.
How to remove the Top Cover
1. Remo ve the Lens Cover. (image 2-2)
2. Pull off the 3 rubber sealing pieces covering the Top Cover screws. (image 2-3)
Tip: Use the flat blade screwdriver to pull off / slide in the tops of the 3 rubber pieces.
3. Turn out the 3 screws connecting the Top Cover to the Projector Frame. (ima ge 2-4)
4. Remo ve the Top Cover.
5. Reverse this procedure to reinstall the Top Cover.
R5976207 ANALYZER KIT FOR G/R 6500/6400I AND SIM6(HB) PROJECTORS 01122003
5