Broan 942236-K1 TV Mount User Manual


 
WARNING: Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
Prepare cabinet.
1. Carefully remove all packing material.
Determine location.
1. Mark the wall to show wall opening size. (See dimension chart) Note:
Commonly accepted height of a medicine cabinet is 64" from the fin-
ished floor to center of mirror area. However, height may be adjusted to
individual preference.
2. Provide 120 VAC power cable through wall, directly behind light box.
(Fig. 7)
Mount cabinet.
1. Cut out wall opening, being careful not to damage the surrounding wall
surface. (Fig. 7) The rough wall opening must be free of all obstruc-
tions. Additional framing must be provided. (Fig. 8)
2. Drill (2) 3/16” diameter clearance holes through the left side of the cabi-
net. Locate holes 1½” in from
inside
top and bottom edges of cabinet
and 1½” from
inside
back of cabinet. Repeat on other side.
WARNING: Before wiring this product, switch power off at service en-
trance and lock service panel to prevent power from being switched
on accidentally.
3. Remove face plate from cabinet.
4. Pull 6" of power cable through access hole in light fixture box and se-
cure cable to box with proper connector.
5. Insert cabinet into wall opening and secure to wall studs through four
clearance holes with mounting screws.
Connect electrical wiring.
1. Strip ½” of insulation from wires. Make electrical connections: black to
black, white to white, and green or bare wires to a permanent ground.
2. Re-attach face plate to cabinet.
Mount shelves and attach mirror doors.
1. Follow instructions on other side of this sheet.
INSTRUCTIONS FOR
BUILT-IN INSTALLATIONS
BROAN ONE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal
use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR
IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
BROAN MFG. CO., INC., 926 West State Street, Hartford, WI 53027
FIG. 7
FIG. 8
DIMENSIONS W x H x D
Size Wall Opening Size
24” 22
5
/
8
x 27
1
/
4
x 3½
30" 28
5
/
8
x 27
1
/
4
x 3½
36" 34
5
/
8
x 27
1
/
4
x 3½