Bryan Boilers K-350-S150-GI VCR User Manual


 
WATER BOILER DIMENSIONS—inches (cm)
ABCDE*FGHI J KL
BOILER Length
Flue Flue Overall Gas Train Supply Return
Width Min. Tube Height Height Floor to
MODEL Over
Location Size Length Connection Nozzle Nozzle
Outside Removal Over Over Flow
Jacket Jacket Clearance Barometric Jacket Nozzle
K-350-W
107
1
/
4
54
1
/
8
24 123
1
/
4
2
1
/
2
NPT 4 FLG 4 FLG 48
1
/
4
32 97
1
/
2
70
1
/
2
73
1
/
2
(272.42) (137.48) (60.96) (313.06) (6.35) (10.16) (10.16) (122.56) (81.28) (247.65) (179.07) (186.89)
K-400-W
117 59 24 133 2
1
/
2
NPT 6 FLG 6 FLG 48
1
/
4
32 97
1
/
2
70
1
/
2
73
1
/
2
(297.13) (149.86) (60.96) (337.82) (6.35) (15.24) (15.24) (122.56) (81.28) (247.65) (179.07) (186.89)
K-450-W
129
3
/
4
65
3
/
8
26 145
3
/
4
2 NPT 6 FLG 6 FLG 48
1
/
4
32 99
1
/
2
70
1
/
2
73
1
/
2
(329.57) (166.05) (66.04) (370.21) (5.08) (15.24) (15.24) (122.56) (81.28) (252.73) (179.07) (186.89)
K-500-W
142
1
/
2
71
3
/
4
28 158
1
/
2
2 NPT 6 FLG 6 FLG 48
1
/
4
32 101
1
/
2
70
1
/
2
73
1
/
2
(361.95) (182.25) (71.12) (402.59) (5.08) (15.24) (15.24) (122.56) (81.28) (257.81) (179.07) (186.89)
K-550-W
155
1
/
2
78
1
/
4
30 171
1
/
2
2
1
/
2
NPT 6 FLG 6 FLG 48
1
/
4
32 103
1
/
2
70
1
/
2
73
1
/
2
(394.97) (198.76) (76.20) (435.61) (6.35) (15.24) (15.24) (122.56) (81.28) (262.89) (179.07) (186.89)
K-600-W
165 83 30 181 2
1
/
2
NPT 6 FLG 6 FLG 48
1
/
4
32 103
1
/
2
70
1
/
2
73
1
/
2
(419.10) (210.82) (76.20) (459.74) (6.35) (15.24) (15.24) (122.56) (81.28) (262.89) (179.07) (186.89)
K-650-W
178 89
1
/
2
30 194 2
1
/
2
NPT 6 FLG 6 FLG 48
1
/
4
32 103
1
/
2
70
1
/
2
73
1
/
2
(452.12) (277.33) (76.20) (492.76) (6.35) (15.24) (15.24) (122.56) (81.28) (262.89) (179.07) (186.89)
Bryan K Series Steam & Hot Water Boilers
Form No. 4950 ©2002 Bryan Steam LLC Printed in USA
13-4428
Bryan Steam LLC Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651 • Internet:www.bryanboilers.com
Fax:765-473-3074
E-mail:bryanboilers@iquest.net
NOTE: * Gas train and control location dimensinos will vary depending on job specifications and conditions.
Dimensions and specifications are subject to change without notice. Consult factory for certified dimensions.
STEAM BOILER DIMENSIONS—inches (cm)
ABCDE* F GHI J KL
BOILER Length
Flue Flue Overall Gas Train
Supply Nozzle
Feed
Width Min. Tube Height Height Floor to
MODEL Over
Location Size Length Connection
15# 150#
Connect.
Outside Removal Over Over Flow
Jacket Jacket Clearance Barometric Jacket Nozzle
K-350-S
107
1
/
4
54
1
/
8
20 123
1
/
4
2
1
/
2
NPT 6FLG 4 FLG 2 NPT 54 32 106
3
/
4
83
3
/
4
88
1
/
4
(272.42) (137.48) (50.80) (313.06) (6.35) (15.24) (10.16) (5.08) (137.16) (81.28) (271.15) (212.71) (224.16)
K-400-S
117 59 24 133 2
1
/
2
NPT 8 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(297.13) (149.86) (60.96) (337.82) (6.35) (20.32) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)
K-450-S
129
3
/
4
65
3
/
8
24 145
3
/
4
2 NPT 8 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(329.57) (166.05) (60.96) (370.21) (5.08) (20.34) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)
K-500-S
142
1
/
2
71
3
/
4
24 158
1
/
2
2 NPT 8 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(361.95) (182.25) (60.96) (402.59) (5.08) (20.32) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)
K-550-S
155
1
/
2
78
1
/
4
24 171
1
/
2
2
1
/
2
NPT 10 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(394.97) (198.76) (60.96) (435.61) (6.35) (25.40) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)
K-600-S
165 83 24 181 2
1
/
2
NPT 10 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(419.10) (210.82) (60.96) (459.74) (6.35) (25.40) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)
K-650-S
178 89
1
/
2
24 194 2
1
/
2
NPT 10 FLG 6 FLG 2 NPT 54 32 110
3
/
4
83
3
/
4
88
1
/
4
(452.12) (277.33) (60.96) (492.76) (6.35) (25.40) (15.24) (5.08) (137.16) (81.28) (281.31) (212.71) (224.16)