Creda ARE200 TV Mount User Manual


 
Notes to the Installer
Test Mode
When the heater is connected via a pilot wire system, the test mode allows the
installer to conrm that the heater is responding correctly to the incoming pilot
wire signal.
Pilot wire mode must be enabled in the heater’s settings in order for the appliance
to be controlled by a Creda controller with pilot wire connection.
Press Menu, Back and Enter for ten seconds to enter the service menu, select
Pilot Wire and press Enter. Select Enable.
Safety - Overheat protection
Note: The comfort
temperature can be
changed later if required.
Note: Some features are
not available while pilot
wire mode is enabled.
Test Mode
Pilot Wire
Status
Comfort
Time
remaining
4:00
Comms
Standalone
RF Module
Pilot Wire
Select
Comfort SP
21 °C
For your safety this appliance is tted
with a thermal cut-out. In the event
that the product overheats for some
reason, the cut-out prevents excessive
temperatures on the product by cutting
the power to the heater. Once the
heater has cooled down, it will reset
automatically, it will continue to cycle on
and o automatically until the reason for
overheating is removed.
The display screen will ash red to
indicate the product has overheated. To
reset the display, remove the obstruction
and hold Enter for 10 seconds.
The desired comfort temperature should be selected
using
and . Press Enter to conrm.
The heater will now enter a test state for four minutes.
During this test state the display screen will indicate
the pilot wire status. Each pilot wire mode should be
veried to ensure correct operation.
6