Datavideo HDR60 DVD Recorder User Manual


 
32
When moving in the normal direction, it will be 0.
BIT-5 SHUTTLE
This bit will be set to 1 when the device goes into SHUTTLE command mode.
Data-6
BIT-4 LAMP REVERSE
This bit will be set to 1 when the device is searching backwards.
BIT-5 LAMP FORWARD
This bit will be set to 1 when the device is searching forwards.
BIT-6 LAMP STILL
This bit will be set to 1 when the device has finished searching.
DATA-8
BIT-0 TRACK IS NOT EMPTY (REC INHIBIT)
If this bit is set to 1, record command will be ignored. (it is not an empty track)
BIT-4 DISK FULL
Set to 1 if the device has reached the end of hard disk.
Data-10
BIT-0 ~ 3 TRACK NUMBER
Track number in BCD.
BIT-4 ~ 8 TENS OF TRACK NUMBER
Tens of Track number in BCD
Data-11
BIT-1 ENCODE SDI
This bit will be set to 1 if the device is encoding SDI source.
BIT-2 DECODE MPEG-2
This bit will be set to 1 if the device is decoding MPEG-2.
BIT-4 ANALOGUE AUDIO
This bit will be set to 1 if the audio input source is analogue.
BIT-5 SDI EMBEDDED
This bit will be set to 1 if the audio input source is SDI embedded audio.
Version History:
Version Description Date FP Revision
1.0 Initial release Jan 2010 V1.0.0
HDR-40 HDR-50 Firmware Version History
Latest version at time of print
MB: 1 . 2 . 23 H