Draper Large Electrically Operated Projection Screen Home Theater Screen User Manual


 
Paragon by Draper Page 2 of 2
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Red
Black
Blue
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Wiring Diagrams
Case Dimensions*
12"
13
1
/4"
5"
8"
2"
1
3
/8"
*
* - Case support brackets will be evenly spaced along the case
2" 2"
2¼"
2¼"
3
1
/
4
"
3
1
/
4
"
2
7
/
8
"
1"
3
/
8
" dia.
1
/
2
" dia.
2
7
/
8
"
2
7
/
8
"
Optional Wall Mounting Bracket
*Please Note: Optional wall brackets add 1¾" per bracket to case length. Wall mounting bracket hole location is 1" from end of case.
www.draperinc.com
(765) 987-799
9
Low Voltage, IR Remote or RF Remote (LVC-III)
* For more information and wiring diagrams for low voltage
multiple motors and network communication, please see
Draper Screen and Lift Controls Planning Sheet, Draper
Screens and Lift Controls Wiring Manual and wiring
diagrams supplied with individual items.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
Dashed wiring by electrician
Low voltage wiring by others
White (Common)
Red (Up)
Black (Down)
Green (Ground)
Location of key
operated on-off
switch if furnished
To
110-120V
Line
Internal Screen Wiring
STOP
Control
Switches
24v DC
STOP
PROJECT:
SUPPLIER:
DATE: REVISED: