Epson CD5220 Flat Panel Television User Manual


 
CD5220 customer display
6.6 DSP-800 mode command list
Command Code description
(hex)
Function descriptions
EOT SOH I n ETB
04 01 49 n 17 select international character
set.
EOT SOH P n ETB
04 01 50 n 17
n=31-58
move cursor to specified
position.
EOT SOH C n m
ETB
04 01 43 n m 17
31<= n<=m<=58
clear display range from n
position to m position and
move cursor to n position.
EOT SOH S n ETB
04 01 53 n 17
n=31-35
save the current displaying data
to n layer for demo display.
EOT SOH D n m
ETB
04 01 44 n m 17
n=31-4F m=31-33
display the saved data
EOT SOH A n
ETB
04 01 41 n 17
n=31-34
brightness adjustment.
EOT SOH F n ETB
04 01 46 n 17
00<=n<=FF
blink display screen.
EOT SOH & n
[px5] ETB
04 01 26 n p1...p5 17,
20<=n
define download characters
EOT SOH ? n ETB
04 01 3F n 17
20<=n
delete download characters.
EOT SOH = n ETB
04 01 3D n 17
n=1 ,2
select peripheral device.
n=1,printer n=2,display
EOT SOH % ETB
04 01 25 17 initialize display
EOT SOH @ ETB
04 01 40 17 execute self-test
Table 6-8
(
REMARK)
*
About the command display the saved data(Table 6-9)
n lay select
n lay select
m show mode
bit 0=1
lay 1 bit 3=1
lay 4
bit 0=1 show mode 1