EverFocus EDSR1600 DVR User Manual


 
In ALARM RECORDING MENU, we define
(1) CH (Alarm input) : Select alarm input or RST for alarm reset input.
(2) OP (OPERATION) : ON : Records when an alarm occurs.
OFF : No reaction when alarms occur.
(3) TYPE : Select alarm type:
N.C. : Normally Closed with time out function counting from alarm start
(set in DURATION)
N.C. + TRANS : Normal Closed, alarm duration as long as contacts is
active + timeout (set in DURATION)
N.O. : Normal Open with time out function counting from alarm start
(set in DURATION)
N.O. + TRANS: Normal Open, alarm duration as long as contact is
active + timeout (set in DURATION)
(4) DURATION : Timeout duration time for each event. 0~99 seconds adjustable.
MENU
16
6.6 ALARM RECORD SETTING MENU
ALARM SETTING MENU
CH OP TYPE DURATION
1 ON N.O 05 SECS
2 ON N.O 05 SECS
3 ON N.O 05 SECS
4 ON N.O 05 SECS
5 ON N.O 05 SECS
6 ON N.O 05 SECS
7 ON N.O 05 SECS
8 ON N.O 05 SECS
9 ON N.O 05 SECS
10 ON N.O 05 SECS
11 ON N.O 05 SECS
12 ON N.O 05 SECS
13 ON N.O 05 SECS
14 ON N.O 05 SECS
15 ON N.O 05 SECS
16 ON N.O 05 SECS
Turn the JOG dial clockwise or counter-clockwise to select the options.
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
Press ENTER key to confirm the option and move to next column.
ENTER