Grundig LXW 102-8625 REF Flat Panel Television User Manual


 
External adjustment
52
RS232C Communication Protocol
11. Sharpness : h
To adjust Sharpness
* Transmission
{h}{ }{SET ID}{ }{Data}{Cr}
Data : Min : 00h~Max : 64h
* Ack
{SET ID}{:}{OK}{x}{Data}{x}
Data : Min : 00h~Max : 64h
12. Information : f
Information on/off
* Transmission
{f}{ }{SET ID}{ }{Data}{Cr}
Data 0 : On
Data 1 : Off
* Ack
{SET ID}{:}{OK}{x}{Data}{x}
Data 0 : On
Data 1 : Off
13. Pip On : o
Pip on/off
* Transmission
{o}{ }{SET ID}{ }{Data}{Cr}
Data 0 : On
Data 1 : Off
* Ack
{SET ID}{:}{OK}{x}{Data}{x}
Data 0 : On
Data 1 : Off
14. Pip Source : u
To Select Pip Source
* Transmission
{u}{ }{SET ID}{ }{Data}{Cr}
Data 0 : TV
Data 1 : Scart 1
Data 2 : Scart 2
Data 3 : Composite 1
Data 4 : S-Video 1
Data 5 : Composite 2
Data 6 : S-Video 2
Data 7 : Component 1
Data 8 : Component 2
Data 9 : DVI
Data 10 : PC
* Ack
{SET ID}{:}{OK}{x}{Data}{x}
Data 0 : TV
Data 1 : Scart 1
Data 2 : Scart 2
Data 3 : Composite 1
Data 4 : S-Video 1
Data 5 : Composite 2
Data 6 : S-Video 2
Data 7 : Component 1
Data 8 : Component 2
Data 9 : DVI
Data 10 : PC
15. Pip Location : n
To Select Pip Position
* Transmission
{n}{ }{SET ID}{ }{Data}{Cr}
Data 0 : Right Bottom
Data 1 : Right Top
Data 2 : Left Top
Data 3 : Left Bottom
* Ack
{SET ID}{:}{OK}{x}{Data}{x}
Data 0 : Right Bottom
Data 1 : Right Top
Data 2 : Left Top
Data 3 : Left Bottom