Heath Zenith UT6028-WH Universal Remote User Manual


 
4 598-1296-02
Motion Sensor Controls
5 1 TEST
ON-TIME
(MINUTES)
RANGE
MAX
MIN
Range Control
LED Indicator
ON-TIME Control
Outdoor Motion Sensor
Motion Sensor Sensitivity
The detector is most sensitive to motion across its eld of view.
Motion
Most SensitiveLeast Sensitive
Motion
Sensor Sensor
Maximum
Coverage Angle
Maximum Range
Motion Sensor Coverage Area
70 ft.
(21 m)
8 ft.
(2.4 m)
180°
Aim Sensor Down
for Short Coverage
Aim Sensor Higher
for Long Coverage
Adjusting Motion Sensor Coverage
3. Adjust RANGE Control. To increase sensitivity, turn the RANGE
control toward MAX. To decrease sensitivity, turn the RANGE
control toward MIN. Note: If the RANGE is set too high, false
triggering may result in some environments.
Note: When using test mode to check operation in the day time:
A. Set the DETECT control switch to DAY/NIGHT and
B. Set the ON-TIME control to TEST.
4. Set ON-TIME Control. Determine the amount of time you want
the connected device to stay on after motion is detected (1 or
5 minutes). Slide the ON-TIME control to the corresponding
setting.
IMPORTANT: Avoid Aiming Control At:
• Objects that change temperature rapidly, such as heating vents,
fans, and air conditioners. These air sources could cause false
triggering.
• Areas where pets or trafc may trigger the control.
• Nearby large, light colored objects reecting light may trigger the
shut-off feature. Do not point other lights at the sensor.