Specifications
Input Specifications
AC Wall Adapter 100 to 240 ±10% VAC input, 5 VDC output, 2A max.
DC terminal +7 VDC to +50 VDC @ 2.5 watts. Actual current
consumption may vary depending on the type of SFP
modules installed. When not using the supplied AC/DC
converter the externally supplied DC power must be
provided from a LPS source
DC jack 5 VDC
Double-USB Power
Cable
Spec 500mA
Please note that the laptop or PC USB ports must be 2.0
or greater to provide sufficient power to the unit.
Power Tray 18-Slot AC
for Miniature Converters
125W, 20A@ 5V
Operating Temperature:
-13°F to +185°F (-25°C to +85°C) DC configuration
-4°F to +158°F (-20°C to +70°C) DIN Railmount power supply
+14°F to +122°F (-10°C to +50°C) with AC wall adapter
Storage Temperature:
-49°F to +185°F (-45°C to +85°C)
Shipping Weight:
0.25 lbs (0.11 kg)
Dimensions:
0.83” H x 1.80” W x 3.35” D (2.11 x 4.57 x 8.51 cm)
Standards/Compliance
SFP-MSA SFP standard (September 14, 2000)
SFF-8472 DDMI standard (Revision 1.0)
All SFPs used in this product should be certified to IEC 60825-1.
Fiber Optic Cleaning Guidelines
Fiber Optic transmitters and receivers are extremely susceptible to contamination by
particles of dirt or dust, which can obstruct the optic path and cause performance
degradation. Good system performance requires clean optics and connector ferrules.