Kathrein CCR 512 Satellite TV System User Manual


 
4.4.4. LNB settings
(1) LNB
{ON} Standard setting
{OFF} Operation without LNB signal (e.g. on special systems with several subscribers)
(2) In standby
{OFF} Standard setting
Attention! Only use the setting {OFF} for individual systems, otherwise the receiver
supplies the LNB with power even in standby. The power consumption
of the receiver can increase from typically 2 watts to up to 10 watts in
standby.
{ON} In standby, the LNB voltage remains switched on, e.g. for supplying power to a system
with several subscribers.
4.4.5. DiSEqC (Digital Satellite Equipment Control)
In the DiSEqC menu, the control signals must be set according to the requirements of your satellite
system.
(1) 22 kHz signal
{OFF} 22 kHz not active
{High/Low} 22 kHz switches between high and low band
{Pos. A/B} 22 kHz switches between 2 satellites
(2) Tone burst
{OFF}
{High/Low} activates the tone burst depending on the receiving frequency
{Pos. A/B} selects the orbit position 1/3 or 2/4
{Opt. A/B} switches between the orbit position 1/2 and 3/4
(3) DiSEqC
{OFF} , {ON} Select {ON}, when you operate the receiver on a DiSEqC compatible satellite
receiving system.
(4) DiSEqC repeat (used for cascaded switching matrices)
{OFF} no repetition of the DiSEqC signal
{ 1 } the DiSEqC signal is repeated 1 time.
{ 2 } the DiSEqC signal is repeated 2 times.
(5) UFO
„UFO mini“ and „UFO micro“ are specific SAT systems from the company Kathrein. Please take the
required parameters from the respective operating manuals.
(1) UFO mini {OFF } / {ON}
(2) Remote Freq. {XXXX}
(3) UFO micro {OFF} / {ON}
With the [M] button, access the main menu. The desired submenus are activated by pressing the
numerical buttons [1]....[X] or the programme buttons [] / []. The selected submenu is then outlined
in colour, and the respective help text appears. This activated submenu is called up by pressing the
[OK] button. The other items in the submenu are accessed in the same manner.
By pressing the [E] button, you can skip one step higher in each menu (or exit the menu).
After exiting the menu with the [E] button, the message „save changes“ appears on the screen. Press
[OK] to save the changes.
- 17 -