Kidde I9040 Universal Remote User Manual


 
Fire Sentry
Battery Operated 4” Smoke Alarm
Model i9040
Technical Specifications
Model Number: i9040
Power Source: 9V Battery (included)
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F to 100˚F (4°C to 38°C)
Humidity Range: up to 85% relative humidity (RH)
Sensor: Ionization
Size: 4” in diameter x 1.45” depth
Weight: .5lbs
Interconnects: No
Warranty: 3 year limited
**Not for sale by individual unit
Ordering Pack Pack Dimensions Case Casesper
Number UPC I2of5 Confg. Quantity (wxdxhinches) Weight pallet
0914 0-25417--00914-9 200-25417-00914-3 BOX Cut Case (12 Units) 6.60 x 13.00 x 4.60 4.55 lbs 168
0914-9960 0-25417--91460-3 200-25417-91460-7 BOX Cut Case (8 Units) 10.30 x 10.70 x 7.60 7.30 lbs 84
0914-040 0-25417--91422-1 300-25417-91422-2 BOX Cut Case (40 Units) 9.00 x 17.00 x 9.00 15.00 lbs 30
0914T-020 0-25417--91422-1 200-25417-91422-5 BOX Cut Case (20 Twin Packs) 9.00 x 17.00 x 9.00 15.00 lbs 60
0914E 0-25417--09145-8 200-25417-09145-2 BOX Master Pack (12 Units) 10.10 x 10.10 x 5.10 5.20 lbs 112
1016 Corporate Park Drive
Mebane NC 27302
1-800-880-6788
www.kidde.com
Distributed by:
KL-i9040 sheet Rev. 1-12-09
Architectural and Engineering
Specifications
The smoke alarm shall be Kidde Model Number i9040
or approved equal. It shall be powered by a 9V battery.
The unit shall incorporate an ionization smoke sensor
with nominal sensitivity of 0.52-1.12%/ft. The tempera-
ture operating range shall be between 40°F and 100°F
(4°C and 38°C) and the humidity operating range shall
be up to 85% relative humidity.
The alarm can be installed on the surface of any wall
or ceiling following the UL/NFPA/Manufacturer’s recom-
mended placement guidelines.
The alarm shall include a test button that will electroni-
cally simulate the presence of smoke an cause the unit
go into alarm. This sequence tests the unit’s electronics,
battery and horn to ensure proper operation.
The unit shall include a piezoelectric horn that is rated
at 85 decibels at 10 feet. The alarm shall produce the
ANSI S3.41 three pulse temporal pattern audible emer-
gency evacuation signal.
The unit shall also indicate a low battery warning utiliz-
ing a brief alarm chirp ever 30-40 seconds for a minimum
of seven (7) days.
The smoke alarm shall at a minimum meet the require-
ments of UL 217, NFPA 72, The California State Fire
Marshall, NFPA 101 (One and two family dwellings
Federal Housing Authority (FHA). It shall also include a
3-year manufacturer’s limited warranty.
Ordering Information
Includes 9V Carbon Zinc Battery