KTI Networks KCD-300 TV Converter Box User Manual


 
FCC Part 15
'
Class B
CISPR 22 Class B
Katron Technologies Inc.
15F-7, No. 79, Sec. 1, Hsin Tai Wu Rd.,
Hsi-chih,
Taipei Hsien, Taiwan.
Tel:886-2-2698-3878
Fax:886-2-2698-3873
E-mail:kti@ktinet.com.tw
URL:http://www.ktinet.com.tw
KTI Networks Inc.
7400 Harwin Dr., Suite 120 Houston,
Texas 77036 U.S.A.
Tel:713-266-3891
Fax:713-914-0555
E-mail:kti@ktinet.com
URL:http://ww
w.ktinet.com
Trademarks: All brand names are trademarks or registered
trademarks of their respective holders.
This information is subject to change without prior notice.
Fiber (FX) Port Multimode ST, SC, Single mode SC
100Mbps Full-duplex and half-duplex support
MMF 50/125µm, 62.5/125µm fiber cable
SMF 9/125µm cable
Far End Fault Indication support
Flow Control IEEE 802.3x for full-duplex, Back pressure for half-duplex
LEDs - Power status
- TP port link, activity, speed, duplex status
- Per FX port link, activity, optical link status
Configuration Setting Switches Auto/forced mode, TP speed, TP duplex FXduplex
DC Power Input Screwed terminator block : 2 pairs of +/- contacts
DC jack : -D 6.3mm / + D 2.0mm
Operating voltage range : +7 - +30VDC
Power Consumption 3W max. @30VDC power input
Dimension 28 x 82 x 95 mm, Weight : 250g
Housing Enclosed metal with no fan
Mounting Support DIN Rail mounting, Panel mounting
Environment Operating Temperature: See ordering information
Storage Temperature: -20
O
C ~ 85
O
C
Relative Humidity: 5% ~ 95% non-condensing
Approval FCC Class B, CE/EMC Class B, EN60950 safety
Fiber Optical Specification :
Model FX &Cable Wavelength Tx Power Rx Sensitivity Rx Max.Power
-T ST MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-C SC MMF 1310nm -19 ~-14 dBm -31 dBm -14 dBm
-C1 SC MMF 1310nm -20 ~-14 dBm -31 dBm 0 dBm
-SA2 SC SMF 1310nm -15 ~-8 dBm -31 dBm -7 dBm
-SL2 SC SMF 1310nm -15 ~-8 dBm -30 dBm -7 dBm
-SL3 SC SMF 1310nm -15 ~-8 dBm -34 dBm 0 dBm
-SL4 SC SMF 1310nm -5 ~0 dBm -35 dBm -3 dBm
-SL10 SC SMF 1550nm -5 ~0 dBm -35 dBm -3 dBm
-W3515 Bi-Di SC SMF Tx 1310nm -14 ~-8 dBm -31 dBm 0 dBm
Rx 1550nm
-W5315 Bi-Di SC SMF Tx 1550nm -14 ~-8 dBm -31 dBm 0 dBm
Rx 1310nm
EMI EMS Safety Environmental Tests :
Ordering Information :
Specifications
Class B
Class B
< 75 W
Clause 5
+/-8KV
Power:+/-4KV
Data:+/-2KV
Level 3
50Hz 40A/m
Interruption : C
Dips : A
Strength:10V/m
TP, 1500VAC/60sec.
TP, 500VDC/10Mohm
-20
O
C, 96hrs
+70
O
C 40%RH 96hrs
+60
O
C 90%RH 96hrs
Test
FCC/EMI
CE/EMC/EMI
CE/EMC/Harmonic
CE/EMC/VFF
CE/EMC/EMS
ESD Test
RS Test
EFT/BURST
Surge Immunity
CS Test
Magnetic Field Imm.
Voltage Dips Imm.
Safety
Dielectric Voltage
Insulation Resistance
Cold Test
Dry Heat Test
Damp Heat Test
Storage Test
Vibration Test
Standard
FCC Rule Part 15
EN55022, CISPR 22
EN 61000-3-2
EN 61000-3-3
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 60950, IEC 60950
IEEE 802.3
IEEE 802.3
IEC 68-2-1 Test Ad
IEC 68-2-2 Test Bd
IEC 68-2-3
IEC 68-2-48
IEC 68-2-34
+85
O
C 40%RH 96hrs
-20
O
C 96hrs
-T
-C
Operating
Temperature
-10 ~ 70
O
C
-10 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
-20 ~ 70
O
C
ST MMF
FX Port
Fiber
Model
KCD-300-xxx
SC MMF
SC MMF-C1
SC SMF-SA2
SC SMF-SL3
SC SMF-SL4
2km
Ref.
Distance
2km
2km
20km
30km
-20 ~ 70
O
C
SC SMF-SL2 20km
40~50km
-20 ~ 70
O
C
SC SMF-SL10 100km
KCD-3PB
Panel mounting
bracket for KCD-300
-20 ~ 70
O
C
Bi-Di SC SMF-W3515 15~20km
-20 ~ 70
O
C
Bi-Di SC SMF-W5315 15~20km
080110