113
Ack
[p][ ][Set ID][ ][OK/NG][Data][x]
1199.. AAbbnnoorrmmaall SSttaattee ((CCoommmmaanndd 22 :: zz))
G To recognize an abnormal state.
Transmission
Data FF : Read
Data 0: Normal (Power on and signal exist)
1: No signal (Power on)
2: Turn the monitor off by remote control
3: Turn the monitor off by sleep time function
4: Turn the monitor off by RS-232C function
5: 5V down
6: AC down
7: Turn the monitor off by Fan Alarm function
8: Turn the monitor off by Off time function
9: Turn the monitor off by Auto sleep function
* This function is “read only”.
[k][z][ ][Set ID][ ][FF][ ][Cr]
Ack
[z][ ][Set ID][ ][OK][Data][x]
2200.. IISSMM MMeetthhoodd
((CCoommmmaanndd 11 :: jj,, CCoommmmaanndd 22 :: pp))
G To control the ISM method. You can also adjust ISM
Method in OPTION menu.
It’s not available to use this function in LCD TV models.
Transmission
[j][p][ ][Set ID][ ][Data][Cr]
APPENDIX
2211.. LLooww PPoowweerr
((CCoommmmaanndd 11 :: jj,, CCoommmmaanndd 22 :: qq))
G To reduce the power consumption of the set. You can
also adjust Low Power in OPTION menu.
It’s not available to use this function in LCD TV models.
Transmission
Data 0 : Off
1 : On
[j][q][ ][Set ID][ ][Data][ ][Cr]
Ack
[q][ ][Set ID][ ][OK/NG][Data][x]
**
RReeaall ddaattaa mmaappppiinngg 11
0 : Step 0
A : Step 10 (Set ID 10)
F : Step 15 (Set ID 15)
10 : Step 16 (Set ID 16)
64: Step 100
6E : Step 110
73: Step 115
74 : Step 116
C7: Step 199
FE : Step 254
FF : Step 255
**
RReeaall ddaattaa mmaappppiinngg 22
0:-40
1:-39
2:-38
28 :0
4E : +38
4F : +39
50 : +40
Data 0: Normal
1: White wash
2: Orbiter
3: Inversion