Alarm Recording (Emergency Recording)
Alarm Recording Operation
Check that a video cassette with its tab intact has
been inserted.
Set the MENU/REC LOCK switch to MENU to
display the menu screens. Press the page button to
display the alarm recording setting screen (Menu
Screen 3) on the TV monitor.
Press the set (+ or –) button to display ALARM for
MODE.
q
w
e
Press the shift ( ) button to move the flashing to
DURATION.
Press the set (+ or –) button to set the recording
duration.
Upon completion of the settings, set the MENU/
REC LOCK switch to OFF. The regular screen is
restored.
If an alarm input signal is subsequently supplied,
the time mode set to 6H, and alarm recording
continues until the alarm is released.
r
t
MODE : ALARM
[ALARM] P3
MODE : OFF
DURATION : 30SEC
[RECALL] -
-
-
DURATION : 30SEC
If TAPE END on Menu Screen 4 has been set to REPEAT, the auto repeat recording mode is established when the
tape comes to the end. When auto repeat recording is to be performed, use an alarm recording interval setting
other than MANUAL.
•With emergency recording, set the unit to the POWER OFF or STOP mode.
Alarm Recall
The date and time when the alarm signal was input can be ascertained on the TV monitor by checking the alarm input
time in the RECALL item on Menu Screen 3.
Set the MENU/REC LOCK switch to MENU to
display the menu screens. Press the page button
to display the alarm recording setting screen (Menu
Screen 3) on the TV monitor.
q
Upon completion of the settings, set the MENU
/
REC LOCK switch to OFF. The regular screen is
restored.
w
[ALARM] P3
MODE : ALARM
DURATION : 30SEC
[RECALL] 10-10-01 20:19
9-14-01 12:05
8-30-01 08:40
6-25-01 04:14
[OUTPUT SELECT]
TERMINAL OUT : ERR WARN
The alarm recall function stores up to 4 alarm input times in the memory and displays them on the screen. If there
have been more than 4 inputs, they will be deleted from the screen in sequence starting with the oldest data.
•When the RESET button is pressed while Menu Screen 3 is on the display, the alarm recall memory can be cleared.