NOTE: Read entire instruction sheet before you start installation and assembly.
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud Wall ................................................................................................................................................4
Installation to Solid Concrete/Cinder Block walls ...................................................................................................................5
Installing Adapter Brackets .....................................................................................................................................................6
Mounting and Removing Flat Panel Screen ...........................................................................................................................8
Tools Needed for Assembly
stud finder ("edge to edge" stud finder is recommended)
drill
• 5/16" (8 mm) bit for concrete and cinder block wall
• 5/32" (4 mm) bit for wood stud wall
level
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This mount is designed to attach the screen 0.33" from the wall. Please refer to manufacturer's installation guide
recommendations for required distance from wall to avoid risk of injury or property damage.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
Wood Stud Included
Wood Beam Included
Solid Concrete Included
Cinder Block Included
Metal Stud Do not attach except with Peerless Metal Stud Accessory Kit
- ACC415;
Brick Contact Qualified Professional (not evaluated by UL)
Other or unsure? Contact Qualified Professional
WARNING