Pioneer RS-232C Flat Panel Television User Manual


 
PDP-614MX External Control Manual
17
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag 01H
DATA01 : BLUE Gain Flag 03H
DATA02 : BLUE Low D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA03: BLUE High D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 01H
DATA01: BLUE Gain Flag 03H