Samsung 400FP-3 Flat Panel Television User Manual


 
Nak
Header
com-
mand
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘N’ 0x18 ERR
ERR : Error code that shows what occurred error is
Screen Size Control
Function
Personal Computer recognizes the screen size of TV / Monitor.
Get Screen Size Status
Header command
ID
DATA Length
CheckSum
0xAA 0x19 0
Ack
Header
com-
mand
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘A’ 0x19
Screen
Size
Screen Size : Screen Size of TV / Monitor (Range : 0 ~ 255, Unit : Inch)
Nak
Header
com-
mand
ID
DATA
Length
Ack/Nak r-CMD Val1
Check
Sum
0xAA 0xFF 3 ‘N’ 0x19 ERR
ERR : Error code that shows what occurred error is
PIP ON / OFF Control
Function
The PC turns the PIP function of a TV or Monitor ON / OFF.
This does not operate in MagicInfo mode.
Get the PIP ON / OFF Status
Header command
ID
DATA Length
CheckSum
0xAA 0x3C 0
Introduction