1. SPECIFICATIONS
70.0 16.5
120.0
Item
Signal Transmission Method Dedicated Remote Controller Cable
DC5V supplied from Indoor Unit
Liquid Crystal
Set Temperature Indication (68 ºF to 86 ºF)
Six Directions Indication
AM and PM 12-Hour Indication (Minute Indication Unit: 1 minute)
Displayed when indoor unit sensor is in use
AUTO, HEAT, DRY and FAN Operation
Push Switch
2
2
Detection using the Sensor in the Remote Controller or
Indoor Unit Temperature Sensor
(The detection result is transmitted to the indoor unit every 5 minutes)
Power Source
Display Panel Type
Functions
Operation Section
Room Temperature Detection
Temperature
Airflow Direction
Time
Temperature Sensor
Display Items
Description
1. When the indoor unit is modified from one for wireless remote controller to that for
wired remote controller, some of the functions becomes unavailable.
Therefore, before such modification, make sure to receive an approval of the client.
Also, the self-diagnostics procedure is changed.
• Unavailable Functions : Refer to "3. FUNCTIONS".
• Self-Diagnostics Procedure : Refer to "4. SELF-DIAGNOSTICS".
2. The mode change or SINGLE/MULTI change-over operation is performed using the slide switch
located inside the rear of the remote controller.
Refer to "APPENDIX B : INSTALLATION INSTRUCTIONS" for details.
NOTE
NOTE
NOTE
4