Sim2 Multimedia C3X Link Projection Television User Manual


 
SIM2 C3X LINK
RS-232C CONTROL SPECIFICATIONS
11
SET YCrCb
AutoSync
BE EF 03 19 00 4C 4E 01 84 08 00 00 00 00 00
00
16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET YCrCb 15kHz
BE EF 03 19 00 85 46 01 84 08 00 00 00 0
0 00 00
0A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET YCrCb 32kHz
BE EF 03 19 00 8F 4C 01 84 08 00 00 00 0
0 00 00
12 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET RGB AutoSync
BE EF 03 19 00 49 4B 01 84 08 00 00 00 0
0 00 00
1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET RGB 15kHz
BE EF 03 19 00 80 43 01 84 08 00 00 00 0
0 00 00
06 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
INPUT 7
(COMP RGB 3) /
SIGNAL TYPE
SET RGB 32kHz
BE EF 03 19 00 46 44 01 84 08 00 00 00 0
0 00 00
0E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET YCrCb
AutoSync
BE EF 03 19 00 49 D2 01 85 08 00 00 00 0
0 00 00
17 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET YCrCb 15kHz
BE EF 03 19 00 80 DA 01 85 08 00 00 00 0
0 00 00
0B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET YCrCb 32kHz
BE EF 03 19 00 8A D0 01 85 08 00 00 00 0
0 00 00
13 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET RGB AutoSync
BE EF 03 19 00 4C D7 01 85 08 00 00 00 0
0 00 00
1B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SET RGB 15kHz
BE EF 03 19 00 85 DF 01 85 08 00 00 00 0
0 00 00
07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
INPUT 8
(COMP RGB 4) /
SIGNAL TYPE
SET RGB 32kHz
BE EF 03 19 00 43 D8 01 85 08 00 00
00 00 00 00
0F 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
RECALL
BE EF 03 19 00 85 EB 01 27 09 00 00 01 0
0 00 00
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SAVE CURRENT
SETTINGS
BE EF 03 19 00 54 D6 01 27 09 00 00 0
0 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
MEMORY 1
SAVE INITIAL
SETTINGS
BE EF 03 19 00 45 9A 01 28 09 00 00 01 0
0 00 00
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
RECALL
BE EF 03 19 00 74 AB 01 27 09 00 00 01 0
0 00 00
02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SAVE CURRENT
SETTINGS
BE EF 03 19 00 A5 96 01 27 09 00 00 00 0
0 00 00
02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
MEMORY 2
SAVE INITIAL
SETTINGS
BE EF 03 19 00 76 DE 01 28 09 00 00 02 0
0 00 00
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
RECALL
BE EF 03 19 00 E4 6A 01 27 09 00 00 01 0
0 00 00
03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SAVE CURRENT
SETTINGS
BE EF 03 19 00 35 57 01 27 09 00 00 00 0
0 00 00
03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
MEMORY 3
SAVE INITIAL
SETTINGS
BE EF 03 19 00 A7 E3 01 28 09 00 00 03 0
0 00 00
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
The response of the unit to a correct Operation Code consists of the byte 1E followed by a copy of the
packet that has been sent to the unit, where, however:
- byte number 11 is set at 01,
- CRC (bytes number 6 and 7) has been altered accordingly.
0 1 2 3 4 5 6 7
1E BE EF
Packet Type Packet Payload Size Packet Checksum (CRC)
8 9 10 11 12 13 14 15 16 17 18 19 20
Op Type
Op ID
01 00
Op Target
00 00
Value
00 00