Sony 158 Flat Panel Television User Manual


 
FWD-42LX1
FWD-32LX1
16
(g) Shutdown Log enquiry
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x30 0x11 0xFF 0xFF 0xC0
Answer Header Answer Return to Data Size Return Data1 Check Sum
Enquiry 0x70 0x00 0x02 Code Table(4-c) 0xXX Completed
Return Data1: 0x00 - 0xFF
Code Table(4-c)
Shutdown Information
bit0 Reserved
bit1 1: FAN operation is abnormal 0: Normal
bit2 1: Backlight is abnormal 0: Normal
bit3 1: Temperature sensor is abnormal 0: Normal
bit4 1: Main power supply is abnormal 0: Normal
bit5 1: Digital power supply is abnormal (3.3 V, 5 V) 0: Normal
bit6 1: Analog supply is abnormal (5 V/9 V) 0: Normal
bit7 1: Scaler is abnormal 0: Normal
Code Table(4-d)
[a]Function [b]Range/Switch code Command
Control Enquiry Standby Power On
0x00 Model Name 0x08 - 0x09 No Yes Enable Enable
0x01 Serial Number 0x001E8480 - 0x002DC6BF Yes Yes Enable Enable
(2,000,000 - 2,999,999)
0x02 Operation Time 0x00000000 - 0xD693A3FF
(0sec._3,599,999,999sec.)
0x03 Soft Version(Main) 0x0000 - 0xFFFF No Yes Enable Enable
0x07 Digital 3.3 V 0x00 - 0xFF
0x09 Digital 5 V 0x00 - 0xFF
0x0A Temp1 0x00 - 0xFF
0x0D Temp(P/S) 0x00 - 0xFF
0x0F Soft Version(Scaler) 0x0000 - 0xFFFF
0x10 Analog5 V/9 V 0x00 - 0xFF
0x11 Shutdown Log 0x00 - 0xFF
0x12 Digital 3.3 V(Failure) 0x00 - 0xFF
0x13 Digital 5 V(Failure) 0x00 - 0xFF
0x14 Analog5 V/9 V(Failure) 0x00 - 0xFF
0x20 Busy to INPUT
*
0x00 Non Busy
0x01 Busy
* Busy to INPUT should be judged by Busy Non Busy. Busy to INPUT may be incorrectly judged during start when it is judged by only Non Busy.