Maintenance
20
P6701B, P6703B, and P6723 Service Manual
Short pin
Figure 3: Location of short interface pin
Removing and Replacing the TekProbe Interface Collar
1. To remove the collar, firmly pull the collar off by hand.
2. To replace the collar, align the smaller group of pins with the smaller of the
two holes in the interface collar and align the tabs with the slots. Gently
press the two pieces together. See Figure 4.
Slot
Tab
Figure 4: Replacing the TekProbe collar