Transition Networks AR-CF-02(SM) TV Converter Box User Manual


 
Installation NOTES
Install Coax Copper
STAR TOPOLOGY
MAXIMUM coax segment to active hub is 600 meters (2000
feet) on RG-62 cable; minimum does not apply.
BUS TOPOLOGY
Devices attached to coax bus must be located AT LEAST six
(6) feet apart.
MAXIMUM coax bus length is 300 meters (1000 feet);
minimum is 1.8 meters (6 feet).
Device(s) attached to EACH END of bus must be terminated.
NOTE: If the media converter is installed at one end of the
bus, use the configuration switch to terminate the media
converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter)
according to site installation requirements:
Switch 1 NOT USED
Switch 2 UP = OFF Media converter TRANSFERS signal
DOWN = ON Media converter TERMINATES signal.
Install Fiber
Connect one end of first fiber cable to AR-CF-02 media
converter TX connector.
Connect other end of that fiber cable to second AR-CF-02
media converter RX connector.
Connect one end of second fiber cable to AR-CF-02 media
converter RX connector.
Connect other end of that fiber cable to AR-CF-02 media
converter TX connector.
Power
Locate correct power supply adapter for site installation.
Connect media converter power connector at end of power
supply adapter cord to AR-CF-02 media converter power
receptacle.
Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Fiber Optic Transmitter Power: min: -19.0
dBm
max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm
Wavelength: 850nM
Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber
Fiber Optic Transmitter Power: min: -27.0 dBm max: -17.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -13.0 dBm
Wavelength: 1300nM
Bit error rate: 10
-9
Maximum Cable Distance: 8 kilometers
COAX CABLE/STAR TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62/u
Impedance: 75 @ 10 MHz
Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz
Maximum Attenuation: 5.5 dB/1000 feet
Maximum Cable Distance: 600 meters (2000 feet)
Minimum Distance/Connection: 0 meters (0 feet)
RG-59 Cable
Cable Characteristics:
Cable type: Coaxial RG-59/u
Impedance: 93 @ 10 MHz
Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz
Maximum Attenuation: 7.0 dB/1000 feet
Maximum Cable Distance: 450 meters (1500 feet)
Minimum Distance/Connection: 0 meters (0 feet)
COAX CABLE/BUS TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62/u
Impedance: 93 @ 10 MHz
Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz
Maximum Attenuation: 5.5 dB/1000 feet
Maximum Cable Distance: 300 meters (1000 feet)
Minimum Distance/Connection: 1.8 meters (6 feet)
AR-CF-02