INSTALLATION
Install E-TX-FX-xx00 at Site
WARNING: During the site installation, handle the E-TX-FX-xx00 in such a
way that the E-TX-FX-xx00 does not fall. Failure to observe this warning
could result in injury to personnel and/or equipment damage.
To install the E-TX-FX-xx00 in 19-inch rack cabinet:
NOTE: Brackets and screws are provided.
1. Install right and left mounting brackets to E-TX-FX-xx00 chassis by
removing two (2) screws from each side of E-TX-FX-xx00 chassis
and then installing those screws through mounting bracket into E-
TX-FX-xx00 chassis.
2. Carefully align the E-TX-FX-xx00 between rack mounting rails.
3. Install E-TX-FX-xx00 in rack by installing two (2) screws through
right front bracket into rack and two (2) screws through left front
bracket into rack, using clip nuts (NOT provided) if necessary.
To install the E-TX-FX-xx00 on table or other flat surface:
NOTE: Rubber feet are provided.
1. Carefully turn E-TX-FX-xx00 to side.
2. Install four (4) rubber feet:
Separate rubber feet.
Remove protective
paper from adhesive
surface on rubber foot.
Position and secure
each rubber foot as
shown.
3. Return E-TX-FX-xx00 to upright position.
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications,
1998 Edition.
Fiber Cable
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Bit error rate: 10
-11
E-TX-FX-xx00, E-TEL-1200 1300 nM
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget 11.0 dB
Typical Maximum Cable Distance:* 2 kilometers
E-TX-FX-xx00(SC), E-TEL-1200(SC) 1300 nM
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget 11.0 dB
Typical Maximum Cable Distance:* 2 kilometers
E-TX-FX-xx00(MT), E-TEL-1200(MT) 1300 nM
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -33.5 dBm max: -14.0 dBm
Link Budget 14.5 dB
Typical Maximum Cable Distance:* 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber
Bit error rate: 10
-11
E-TX-FX-xx00(SM), E-TEL-1200(SM) 1300 nM
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm
Link Budget 16.0 dB
Typical Maximum Cable Distance:* 20 kilometers
E-TX-FX-xx00(LH)**, E-TEL-1200(LH)** 1300 nM
Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget 26.0 dB
Typical Maximum Cable Distance:* 40 kilometers
*Actual distance dependent upon physical characteristics of network installation.
**Requires a minimum loss of 5 dB over cable or damage to receiver may occur.
1
3
2
1
4
3
2
5
6
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
7
10
9
8
11
12
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
ACT
FBR LINK
TP LINK
POWER