Transition Networks J/E-CX-TBT-01 TV Converter Box User Manual


 
Troubleshooting
If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:
1. Is the
PWR
LED on the media converter illuminated?
NO
Is the power cord properly installed in the media converter and at the
external power source?
Does the external power source provide power?
Contact Technical Support. US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 2.
2. Is the TX
LNK/ACT
LED on the media converter illuminated OR
flashing?
NO
Check twisted-pair 10Base-T cables for proper connection.
Verify that 10Base-T cable is correct (straight-through or crossover)
configuration for site installation (see page 4).
Contact Technical Support. US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the TX
LNK/ACT
LED on the media converter illuminated BUT
NOT flashing?
NO
Disconnect and reconnect the cable to restart the initialization
process.
Restart the workstation to restart the initialization process.
Contact Technical Support. US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 4.
4. Is the
BNC ACT
LED on the media converter illuminated?
NO
Check 10Base-2 cables for proper connection.
Verify that 10Base-2 cable connections on media converter and on
attached device are terminated properly.
Disconnect and reconnect the cable to restart the initialization
process.
Restart the workstation to restart the initialization process.
Contact Technical Support. US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Contact Technical Support. US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
6
J/E-CX-TBT-01
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: J/E-CX-TBT-01 Series Media Converters
Part Number(s):
J/E-CX-TBT-01
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
J/E-CX-TBT-01
to which this declaration refers is in
conformity with the following standards.
CISPR 22:1993; EN 55022:1998 Class A; FCC part 15 subpart B
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
March 16, 2001
Stephen Anderson, Vice-President of Engineering Date
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, USA
telephone: 952-941-7600
toll free: 800-526-9267
fax: 952-941-2322