Transition Networks SSDTF1014-100 Cable Box User Manual


 
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)R LED on the media converter illuminated?
NO
Is the power adapter the proper voltage and cycle frequency for the
AC outlet?
NOTE: Refer to the Power Supply Requirements on page 7.
Is the power adapter properly installed in the media converter and
in the outlet?
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 2.
2. Is the SDF (Signal Detect/Fiber) LED illuminated?
NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 3.
3. Is the SDC (Signal Detect/Copper) LED illuminated?
NO
Check twisted pair cables for proper connection.
Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.
Check integrity of device attached to media converter by twisted-
pair cable.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
NOTE:
T1 must be selected (
LEFT
SWITCH SET
#4 UP) for
RIGHT
SWITCH SET
to have any effect.
If E1 is selected (
LEFT SWITCH SET
#4 DOWN), RIGHT SWITCH SET
is
ignored and the default is E1
3.0V 120cable.
If T1 and short haul are
selected (
LEFT SWITCH SET
#3
UP, #4 UP), but
RIGHT SWITCH
SET
is not set to a valid short
haul value, the short haul
default is DSX-1 0-133 cable.
If T1 and long haul are
selected (
LEFT SWITCH SET
#3
DOWN, #4 UP), but
RIGHT
SWITCH SET
is not
set to a valid
long haul value,
the long haul
default is 0db
100cable.
LONG HAUL Switch Settings*
12
12
12
12
-22.5db
100 ohm cable
-15db
100 ohm cable
-7.5db
100 ohm cable
0db
100 ohm cable
1 2 3 4
*Right switch set #4 not used
12
12
12
12
Transmit All Ones onto TP
on loss of FiberCarrier Detect
UP= Enabled
T1/E1 Selection
UP= T1
Long Haul/Short Haul (T1 only)
UP= Short Haul
Transmit All Ones onto Fiber
on loss of TP Carrier Detect
UP= Enabled
1 2 3 4
NETWORK Switch Settings
KEY
= UP
= DOWN
SHORT HAUL Switch Settings*
12
12
12
12
12
12
DSX-1 533'-655'
100 ohm cable
DSX-1 399-533
100 ohm cable
DSX-1 266-399
100 ohm cable
DSX-1 133'-266'
100 ohm cable
DSX-1 1 0-133
and ANSI T1.403
100 ohm cable
DSX-1 6.0V
100 ohm cable
1 2 3 4
*Right switch set #4 not used
1 2 3 4
1 2 3 4
toward network connectors
toward chassis
LEFT SWITCH SET
1 2 3 4
1 2 3 4
toward network connectors
toward chassis
RIGHT SWITCH SET