ViewSonic VSXXXXX Flat Panel Television User Manual


 
25
e. Adjust sRGB (sRGB) color-temperature
1. Switch the Chroma-C7120 to RGB-mode (with press “MODE” button)
2. Switch the MEM.channel to Channel 4 (with up or down arrow on Chroma-C7120)
3.The LCD-indicator on Minolta-CA210 will show x = 313 ±12, y = 329 ±12, Y = 80 ±15 cd/m
2
10. press “1” key to save adjust value and exit .
Turn the POWER-button off to on to quit from factory mode, and reset the monitor.
Max Brightness measurement: >250 cd/m
2
Test conditions:
a. Switch to the full white pattern, in user mode main menu:
1. Set <Color Settings> Red, Green, and Blue to the max.
2. Set <Brightness> Brightness, Contrast to the max.
5.2 Firmware Upgrade Procedure
5.2.1 Equipment needed:
- VG2427wm
- PC (Personal computer)
- LPT cable
- Firmware upgrade program
ISP Board