Viper 1100.5 TV Cables User Manual


 
17
© 2002 Directed Electronics, Inc
1.
IInnppuutt//OOuuttppuutt SSiiggnnaall
- Connect
these RCA jacks as described in the
Front Panel Connection/Controls
section of this guide.
2.
RReemmoottee SSuubb LLeevveell CCoonnttrrooll
- Connect
the Remote Sub Level control to the
1100.5 only. The 1100.5 control
panel subwoofer adjustments are
used first to set the overall gain for
all synced amplifiers, then the
Remote Sub Level control can
adjust the gain of all synced ampli-
fiers by adjusting its control knob.
3.
SSiiggnnaall CCoonnnneeccttiioonn
- Connect an RCA
cable between the BRIDGE OUT
jack of the 1100.5 and the SLAVE
IN jack of the slaved d600.1 as
shown in Figure 6.
4.
SSllaavvee//MMaasstteerr SSwwiittcchh
- Set the
slave/master switch of the slaved
d600.1 to the slave position. This
will put the I/O RCA jack in the
SLAVE IN mode so it will accept the
audio signal from the 1100.5’s
sync out RCA jack.
NNOOTTEE::
There is only one master when syncing amplifiers.
5.
SSuubbwwooooffeerr SSppeeaakkeerr CCoonnnneeccttiioonn
- In
this amplifier combination the
subwoofer output terminals of both
amplifiers drive a common
subwoofer load. Use the speaker
connection diagram in Figure 6
when connecting the subwoofers to
the amplifiers. Connect the ampli-
fier’s speaker terminals to any
combination of one or more
subwoofers that results in a
nominal impedance between 2 and
4 ohms. DO NOT connect loads of
less than 2 ohms when connecting
to amplifiers in the External Synced
Bridged combination.
WWAARRNNIINNGG::
Two wires of 12AWG minimum must be
connected between the negative sub out termi-
nals of the master and slave amplifiers.
EXTERNAL SYNCED BRIDGED CONNECTIONS/SETTINGS