2
Keep the following items in mind when installing the system:
1. Each of the RF splitters used
must be
DC passing types, such as the Xantech models 200-00 (2-way)
and the 202-00 (4-way), as shown.
2. Note that model 203-00 DC Blockers are used on the two coax leads going to the two TV sets in
the rooms
not
having IR receivers. This is
a must
to prevent the RF inputs on the two TV sets from
"shorting out" the IR control signals.
3. If an RF amplifier(s) is used anywhere in the line of coaxial cable between the CPL94B Coupler and
the INJ94 Injectors, you
must
use a Xantech BYPASS94 Kit to route the IR control signals around the
amplifier(s). See Fig. 4.
4. Where possible, place RF amplifiers ahead of the CPL94B Coupler, as shown in Fig. 3, instead of
using a bypass kit.
5. For information on how to connect and configure modulators and RF amplifiers, refer to ChannelPlus
®
technical information.
282M &
283M
IR Emitters
(included
with 172-94)
MAIN ROOM
RF IN OUT TO TV
RF IN
OUT TO TV
TV SIGNAL PATH
IR REMOTE CONTROL PATH
Hand Held
Remote
REMOTE ROOM
RF IN
2ND
TV
Hand Held
Remote
REMOTE ROOM
120 V AC
(unswitched)
RF IN
3RD
TV
IN
OUT
OUT
Satellite Dish
Coaxial Cable
(not included)
Place emitters on
the IR sensor
window on front
panel of each
controlled unit
(see text).
Emitter
SATELLITE
RECEIVER
(Back Panel)
VCR
(Back Panel)
Emitter
IR Sensor Windows
(Front Panel)
Coaxial Cable
(not included)
Coaxial Cable
(included
with 172-94)
Coaxial Cable
(included with 172-94)
CPL94B COUPLER
(included with 172-94)
Room-to-Room Coaxial Cables
(not included)
200-00
RF SPLITTER
2-Way DC Passing
(not Included)
291-00 IR
RECEIVER
(included)
Coaxial Cable
(included)
781C-00
Power Supply (included)
120 V AC
(unswitched)
291-00 IR
RECEIVER
(included)
Coaxial Cable
(included)
INJ94 INJECTOR
(included)
781C-00
Power Supply (included)
1ST
TV
RF IN
+12 V
IR
RCVR
TV
INPUT
INJ94 INJECTOR
+12 V
IR
RCVR
TV
INPUT
INJ94 INJECTOR
Coaxial Cable
(not included)
EMITTER
REMOTE TV
SAT/VCR
CPL94B COUPLER
EMITTER
IN
OUT
OUT
200-00
RF SPLITTER
2-Way
(not included)
Coaxial Cable
(not included)
INJ94 INJECTOR
(included)
Fig. 2 Applying One 172-94X Kit For a Second Remote Rooms
172-94X