1 ï
6
Replacement of welding fi lter
The welding fi lter can be removed and replaced according to fi gure C:1
and E:1 - E:2.
Replacement of inner protection plate
The welding fi lter must be removed to replace the inner protection plate.
The used inner protection plate is removed as illustrated in fi gure D:1. The
new inner protection plate should be inserted after the protective fi lm is
removed as illustrated in fi gure D:2.
Magnifying lens (accessory) mounting (see fi gure D:3).
Replacement of batteries
The welding fi lter must be dismounted from the welding shield to access
the battery compartments. Take out the battery holders (use a small
screwdriver if necessary). Insert new batteries in the battery holders
according to fi gure G:1. Slide each battery holder into the welding fi lter
until it snaps in position. Note that all settings will be reset to the original
manufacturing setting.
Speedglas 9100V and Speedglas 9100X has a solar panel (see fi g A:3) to
assist the batteries.
Replacement of headband
The headband can be replaced according to fi gure F:1-F:2.
Replacement of sweatband
The sweatband can be replaced according to fi gure F:3.
CAUTION
The used batteries/worn out product parts should be disposed of according
to local regulations. The welding fi lter should be disposed of as electronic
waste.
Extended coverage
Extended head and neck cover (accessory) mounting (see fi gure H:1 –
H:2).